Flexible multi-stack super-resolution of clinical brain MRI using heterogeneous-orientation variational encoding: expert reader evaluation in a Nigerian cohort

Flexible Multi-Stack Super-Resolution of Clinical Brain MRI Using Hetero-Orientation Variational Encoding: Expert Reader Evaluation in a Nigerian Cohort

Computer visionHealthcare & bio Advanced cs.CV

The authors built MS-HVED, which fuses axial, coronal and sagittal MRI stacks with a field-of-view-aware product of Gaussians, and it received higher image quality ratings than a supervised baseline in a reader evaluation on Nigerian clinical data.

Problem

Clinical brain MRI, especially in low-resource settings, mainly uses fast 2D acquisitions with thick slices, so through-plane resolution is low. Stacks in different orientations differ in tilt, alignment and coverage, so they only partly overlap. Existing learning-based super-resolution either uses a single stack or assumes a fixed, ideal multi-stack configuration.

Method

Each available orientation stack is turned into a multi-scale Gaussian posterior by an independent encoder. These are fused with a Product-of-Gaussians whose precision is adjusted by orientation-specific, voxel-wise field-of-view (FOV) masks, reducing the contribution of regions that were not imaged. A shared decoder reconstructs an isotropic high-resolution volume, so the model works with any combination of 1 to 3 stacks without retraining. Training used physics-based domain randomization to simulate anisotropic resolution, slice profiles, oblique acquisitions, partial FOV, motion ghosting, k-space artifacts, bias fields and Rician noise.

Results

Limitations

The reader evaluation covers 44 real cases. The rated items are image quality measures such as overall quality, SNR, artifacts and anatomical consistency; diagnostic accuracy was not measured directly. Training relies on synthetic low-resolution data, and real clinical data has no high-resolution ground-truth images, so quantitative validation is limited. The provided text was truncated, so a detailed analysis of the risk of hallucinated structures could not be checked.

Why it matters

In clinical settings where low-end scanners and short acquisition protocols are common, this method can combine already-acquired images in several orientations into a high-resolution 3D image. External validation on a population underrepresented in medical imaging research, such as in Africa, is also significant.

Key terms

Multi-stack super-resolution
A technique that combines several sets of low-resolution images taken in different orientations to reconstruct a single isotropic high-resolution 3D image.
Product-of-Gaussians
A method that combines several Gaussian distributions into one by multiplying them. Inputs with higher confidence (precision) have more influence on the result.
Domain randomization
A technique that randomly varies training data properties such as contrast, resolution and artifacts over a wide range so the model generalizes to the many conditions found in real settings.
FOV (field-of-view) mask
A mask that marks, voxel by voxel, the spatial region each stack actually imaged. It is used to reduce the influence of regions that were not imaged.

Original

Authors: Kabir Hamzah Muhammad, Lorena Garcia-Foncillas Macias, Soumya Snigdha Kundu, Emily Guilhem, Jon Cleary, Amal Saleh Nour, Yodit Abraham Yaynishet, Chinasa Kalaiwo, et al. · Posted 2026-11-16 · License arXiv 비독점 배포 라이선스 · Based on the full text

This review is an AI-written summary of the paper. Please treat the original paper as the reference.